Biotage Endeavor replacement
Replace it with the H.E.L ChemSCAN range — parallel high-pressure catalyst screening without the 7 mL and 40 bar ceilings
The Biotage® Endeavor™ has been discontinued. If you run one, the question is no longer how it compares — it is what replaces it, and whether you take the chance to lift the limits you have been working around. The ChemSCAN family keeps the parallel, gas-uptake workflow your team already knows, and removes the ceilings.
Why replace your Endeavor
No new units are made
The Endeavor is discontinued. Spares, service and software support can only reduce from here, and an unsupported high-pressure instrument is hard to justify in a safety review.
Only Biotage makes the liners
Biotage’s own FAQ says the glass liners are “custom made for Biotage” — you cannot buy them anywhere else. On an instrument that is no longer made, that means when the liners run out, the instrument stops.
The limits cannot be raised
7 mL, 40 bar, no sampling and no cooling are built into the design. They are not settings you can turn up, and no upgrade raises them — so chemistry that outgrows them has to move to another instrument.
Specification comparison
Endeavor figures come from Biotage’s own published FAQ; ChemSCAN figures from ChemSCAN brochure v1.9.
| Specification | Biotage Endeavor | ChemSCAN SA | ChemSCAN | ChemSCAN+ |
|---|---|---|---|---|
| Reactor zones | 8 | 4 or 8 | 4 or 8 | 4 or 8 |
| Working volume | 1 – 7 mL 1 – 5 mL, blade impeller |
3 – 400 mL | 3 – 400 mL | 2 – 400 mL |
| Reactor vessel sizes | Fixed glass liners | 16 – 500 mL | 16 – 500 mL | 16 – 500 mL |
| Maximum pressure | 40 bar (600 psi) | 100 bar (200 bar optional) | 100 bar (200 bar optional) | 100 bar (200 bar optional) |
| Temperature range | Up to 200 °C | Ambient – 200+ °C | Ambient – 200+ °C | 25 – 200 °C |
| Active cooling | None — 200 °C to ambient takes a couple of hours | −40 °C option with circulator | −40 °C option with circulator | −40 °C option with circulator |
| In-run sampling | Not available | Sampling port option | Sampling port option | Sampling port option |
| Liquid dosing | Not offered | Optional, 0.02 – 40 mL/min | Optional, 0.02 – 40 mL/min | Optional, 0.02 – 40 mL/min |
| Vessel material | Glass liners, custom-made for Biotage | SS316 or Hastelloy HC276 | SS316 or Hastelloy HC276 | SS316 or Hastelloy HC276 |
| Gas feed control | Individual pressure transducer and gas valve per vessel | 2, shared, manually controlled | 3, shared, automated | 3, individual, automated |
| Sensors | Temperature and pressure | Temperature, pH, DO, conductivity, redox | Temperature, pH, DO, conductivity, redox | Temperature, pH, DO, conductivity, redox |
| Analytical integration | Data exported to tab-delimited text | WinISO — GC-MS, HPLC and MS integration with feedback control | WinISO — GC-MS, HPLC and MS integration with feedback control | WinISO — GC-MS, HPLC and MS integration with feedback control |
Two rows are worth reading honestly. On gas feed control Endeavor already regulates each vessel individually, which puts it level with ChemSCAN+ and ahead of SA and ChemSCAN. On temperature both reach 200 °C. The case for replacing it rests on scale, pressure, sampling, cooling and materials — not on every line of the table.
What you gain
From 7 mL to 400 mL
Endeavor tops out at 7 mL. ChemSCAN+ runs 2 – 400 mL on one platform, so conditions found at screening scale are confirmed at working scale without changing instrument.
40 bar becomes 200 bar
Endeavor’s relief valve releases at 40 bar. ChemSCAN+ runs to 100 bar as standard and 200 bar as an option — where much hydrogenation and carbonylation chemistry actually sits.
Sampling during the run
Endeavor has no sampling — you infer progress from gas uptake, or quench reactors at staggered times to imitate a time course. ChemSCAN vessels take a sampling port, so one experiment gives a real profile.
Cooling, not just heating
Endeavor has no active cooling; 200 °C to ambient is a couple of hours of passive decay. ChemSCAN reaches −40 °C with a circulator and controls the descent.
Hastelloy, not sole-source glass
ChemSCAN uses SS316 or Hastelloy C276 vessels rated to 200 bar and 350 °C — so corrosive and halide chemistry is in scope, and the consumable is not tied to one supplier.
Which ChemSCAN replaces your Endeavor?
| If… | Choose | Why |
|---|---|---|
| You want the closest like-for-like | ChemSCAN+ | Endeavor already gives every vessel its own gas valve, so ChemSCAN+ is the direct equivalent — three individual automated gas feeds, plus the scale, pressure and sampling Endeavor never had. |
| You mainly ran routine optimization | ChemSCAN | Automated, independent pressure control with three shared gas feeds. The right choice unless you genuinely fed reactors differently from one another. |
| You need the lowest-cost replacement | ChemSCAN SA | Independent temperature and stirring per zone with manual pressure profiling — still clears the 7 mL and 40 bar ceilings, at the lowest entry point. |
All three run up to 8 zones and are customisable to your chemistry. If you are unsure which fits, tell us what you actually ran on the Endeavor and we will map it.
Biotage Endeavor: frequently asked questions
Is the Biotage Endeavor discontinued?
What replaces the Biotage Endeavor?
What is the maximum pressure of the Biotage Endeavor?
What working volume does the Biotage Endeavor handle?
How many reactors does the Biotage Endeavor have?
Can you take samples during a reaction on the Endeavor?
Does the Biotage Endeavor have cooling?
Are Biotage Endeavor glass liners still available?
What is the difference between the Biotage Endeavor and ChemSCAN+?
Is the ChemSCAN a like-for-like Endeavor alternative?
Sources
Endeavor specifications: Biotage® Endeavor™ Frequently Asked Questions, part number PPS368, © Biotage 2015. ChemSCAN specifications: ChemSCAN brochure v1.9. Biotage® and Endeavor™ are trademarks of Biotage AB, used here only to identify the product being replaced. H.E.L Group is not affiliated with, endorsed by, or a distributor for Biotage AB.
Replacing an Endeavor?
Tell us the chemistry, the scale you need to reach and the pressure you run at, and we will tell you which ChemSCAN fits — or if it does not.