Screening hydrogenation catalysts in parallel means running many reactions at once under controlled hydrogen pressure and temperature, so catalysts and conditions can be compared in one experiment rather than one at a time. The right equipment depends on how much information you need from each reaction.
Step 1: compare catalysts under identical conditions
The CAT vessels are manual: a single pressure vessel holding 7, 18 or 24 glass vials on a stirrer hotplate, where every vial sees the same temperature and pressure. That makes them excellent for replicates and straight catalyst comparisons, and very cost-effective. ChemSCAN reactors are independently controlled — different temperatures and pressures in the same run — and each one measures gas consumption in real time, so you get kinetics rather than just an end point.
For higher throughput, the DigiCAT 96 runs up to 96 simultaneous reactions.
Step 2: measure how fast each catalyst works
When an end point is not enough, you need kinetics: hydrogen uptake measured in real time, reactor by reactor. The PolyBLOCK High Pressure and AutoMATE High Pressure run stainless steel or Hastelloy reactors at up to 200 bar with gas-consumption rate calculation, and the ChemSCAN range runs four or eight pressure reactors at up to 100 bar (200 bar optional) with real-time gas uptake per reactor — resolved to 0.04 mmol, equal to a 0.1 bar pressure change.
Automation and gas feeds. ChemSCAN SA is semi-automatic and upgradable — independent temperature and stirring in every zone, with pressure, feeds and venting controlled manually, and two shared gas feeds. ChemSCAN is automatic, with the reactors operating simultaneously under a shared automated gas feed and three shared feeds. ChemSCAN+ is automatic with each reactor operating independently, so it can be fed, vented and purged on its own, with three dedicated gas feeds per reactor. All three run up to 8 zones.
Step 3: move to continuous flow
Once the catalyst is chosen and the process has to run continuously, FlowCAT takes it into fixed-bed continuous flow. Running a fixed or trickle bed continuously logs conversion and selectivity against time-on-stream, so catalyst deactivation is measured directly rather than inferred.
How many reactions can run at once?
From 7, 18 or 24 vials on the manual CAT units, up to 96 simultaneous reactions on the DigiCAT 96, and up to 8 independently controlled reactor zones on the ChemSCAN — each with real-time gas-consumption measurement. Four-zone ChemSCAN platforms also take the CAT 18 and CAT 24 assemblies, giving 18 or 24 vials at 0.2 – 1.3 mL.
What pressures and temperatures are available?
Up to 100 bar and 250 °C on the manual CAT units (300 °C if pressure is 10 bar g or below), and up to 100 bar with ambient–200 °C on the DigiCAT 96. ChemSCAN runs 1–100 bar as standard with a 200 bar option, ambient to 200 °C, and down to −40 °C with a circulator. FlowCAT runs ambient to 100 bar with a 200 bar option, and ambient to 300 °C with tailored solutions for sub-ambient operation or heating to 550 °C.
What else are these systems used for?
High-pressure catalytic reactions with one or more gas feeds — most commonly hydrogenation, along with carbonylation, oxidation, syngas chemistry, Fischer–Tropsch synthesis, biofuel research and petrochemical processing, across both heterogeneous and homogeneous catalysis.
Explore catalysis and hydrogenation systems → · Talk to a specialist →